KONTAKT
Ørstedsgade, Rudkøbing
Ørstedsgade 26
5900 Rudkøbing
Kristian Dragsbæk Raun
Region Syddanmark
T: 76631934
E: kristian.raun@rsyd.dk
Site owner:
Region of Southern Denmark
Temporary test site - Former dry cleaner - contaminated with PCE
Testsite until medio 2018.
Præsentation af sitet
This is a temporary testsite until medio 2018, when the building will be demolished. The building is a residential house with two small businesses. At the moment the building is empty but heated.
The testsite can be used to test different investigative approaches which can not be tested normally due to tenants.
- uppermost to meters are earth fill
- 2-5 m.b.s. moraine clay
The testsite are polluted with PCE. The hotspot are situated below the building and the indoor air are heavily polluted. For more information please see the attached documents.
Beskrivelse
The project aim is to construct an equipment package that can be deployed at sites with possible vapor intrusion through sewers. Based on this package, two sewers at the test site will be investigated with on-line logging of (i) barometric pressure and temperature, (ii) differential pressure between sewer/downpipe and restroom air or between the restroom and outdoor air, (iii) VOC/CVOC-concentration in the sewer/downpipe, (iv) VOC/CVOV-concentration in the restroom. Based on an analysis of the interrelationships of the dynamic parameters, the equipment will be “armed” for automatic extraction of worst-case samples (using carbon tubes) that can be sent to the lab for analysis and used in risk assessments. Test procedures for quantitative estimation of the sewer contribution will be explored.
Projektdokumenter
Beskrivelse
The purpose of the project is to investigate the effect of ventilating the contamination concentration in waste water pipes and behind water traps. The idea of ventilating the waste water pipe is to dilute the contamination in order to reduce the concentrations that occur in waste water pipes. To further support the investigations of the dynamic in the system, measurements in the waste water pipe is carried out with different spacing behind the water traps, e.g. right behind the water traps, 1 m, 2 m and 3 m behind the water traps depending on how far back it is possible to measure.
Projektdokumenter
Beskrivelse
Continuous measurement of PCE in indoor air with FROG4000Continuous measurement of PCE in indoor air with FROG4000
Projektdokumenter
- Kontinuerlig måling af PCE i indeklima - FROG4000, Rambøll
- Kontinuerlig måling af PCE i indeklima - FROG4000, Rambøll
- Kontinuerlig måling af PCE i indeklima - FROG4000, Rambøll
- Kontinuerlig måling af PCE i indeklima - FROG4000, Rambøll
- Kontinuerlig måling af PCE i indeklima - FROG4000, Rambøll
- Kontinuerlig måling af PCE i indeklima - FROG4000, Rambøll
- Kontinuerlig måling af PCE i indeklima - FROG4000, Rambøll
Beskrivelse
Examination of methods for passive collection of volatile contaminants in sewer.
Projektets idé er at udvikle simple metoder til udførelse af længerevarende passive luftmålinger i boligers afløbssystem for at optimere grundlaget for vurdering af forureningsbidraget til indeluften fra kloakken.Projektets idé er at udvikle simple metoder til udførelse af længerevarende passive luftmålinger i boligers afløbssystem for at optimere grundlaget for vurdering af forureningsbidraget til indeluften fra kloakken.
Projektdokumenter
Beskrivelse
Traditional ventilation of sewers and waste water pipes above roofs is at risk of creating a larger spreading of the contamination in the waste water pipe in the building, as it creates an airflow from the nearest manhole and thought to the waste water pipe in the building. This will draw the contamination into the building. If indication of the ventilation of the waste water pipe at the site actually creates a risk of increased spreading of the contamination to the indoor air, a new test will be carried out with the attempt to turn the airflow in the waste water pipe, changing the air intake to the collection pit to an air discharge and install a temporary active suction in order to assess the derived effect.
Projektdokumenter
Beskrivelse
The purpose of the project is to gain experience of the importance of where the ventilation of the waste water pipe is positioned. Is it e.g. positioned at the top, in the middle or at the bottom, and which mechanisms and conditions govern the intrusion and the leaking from the sewer/waste water pipes to the indoor air? In other words, what kind of dynamic causes a spread from waste water pipes and water traps to the indoor air, and what is the effect of ventilating the waste water pipe?
Projektdokumenter
Beskrivelse
The project aim is to test an approach to estimate the contaminant mass flux to the sub-slab passive venting system, using various test procedure set-ups. The perspective is that the results can lead to a suggested test protocol for application at other/future sites; a protocol that might enable us to estimate the operating time frames at sites with passive venting systems.
Beskrivelse
The project aim is to test and introduce the latest visual technologies applied in various other fields to the environmental professional community. The technologies explored in this project, range from 360° photography and photo optic surveying, visual walks, digital site plans, virtual reality, 3D modeling of the indoor environment and drone video filming/photography.
Projektdokumenter
Praktisk
Access is easy with car. But access with big machinery is limited.
Water, electricity.
You need permission from Region of Southern Denmark before any visits and tests.
Kommende projekter
Region of Southern Denmark are planning different tests in the next 3/4 year and your projekt, if accepted, need to be finished before we demolish the building by the end of 2018.